CSI Division 08 / sq ft / linear ft / each

Curtain Wall Estimating Services United States

Elevation-by-elevation takeoffs for stick and unitised curtain wall packages, interfaces and installation allowances.

Quote response and delivery date confirmed after document review.

ONE DRAWING SET. THREE CLEAR OUTPUTS.

Glass, metal and openings — separated.

01 / GLASS

Glass area & lite counts

Glass designation, make-up, panel count and measured area, grouped by opening and elevation. Gross and fabrication bases stay distinct.

02 / METAL

Framing profile register

Heads, sills, jambs, mullions and transoms by system and profile. Cut lengths and waste require an agreed basis.

03 / OPENINGS

Doors & hardware sets

Entrances, doors and hardware by mark, with supply, installation and unresolved responsibilities visible.

Measurement output: sq ft / linear ft / each. Pricing, manufacturer deductions and procurement quantities are confirmed separately.

MEASURED SCOPE / VISIBLE LIMITS

What your curtain wall estimating package covers

PackageMeasurement scopeBasis to confirm
Facade modulesSeparate vision, spandrel, shadow-box and infill types by elevation and level.Repeated floors require a documented exception and revision register.
Members and fixingsList mullions, transoms, pressure plates, covers and specified anchors.Bracket and anchor quantities follow details; engineering is outside quantity measurement.
InstallationIdentify fabrication, packing, cranage and access inputs for a priced brief.Use project-specific durations, quotations and trade responsibilities.

United States: tender and specification basis

Keep glass areas, framing lengths and opening counts in the units prescribed by the US bid documents. Separate union or open-shop labour inputs when pricing is commissioned.

Include state, county, city, bid deadline and project-specific product evaluation references. Wind, seismic and energy requirements stay with the responsible design team.

08 44 13 glazed aluminium curtain walls, where specified. Specification references describe the tender scope; they do not certify design, product or code compliance.

INSPECT THE OUTPUT

A drawing reference behind every row

Inspect the illustrative elevation breakdown, workbook and annotated drawing. These examples demonstrate the output structure and are labelled as illustrations.

Open sample package →
ILLUSTRATIVE / EX-01 REV A / NOT FOR FABRICATIONCW-NL1L4L2L5L3L630 × 20 ft grossCW-SL1L4L2L5L3L630 × 20 ft grossReference geometry only; confirm profiles and glass deductions.
Diagrammatic, not to scale. Gross opening dimensions and shown lite counts match the workbook; fabrication sizes remain unresolved.

Where glazing bids lose scope

REVIEW / 01

Structural embeds missed on S-sheets

Check the current detail, record the quantity basis and assign a named scope question before bid approval.

REVIEW / 02

Membrane tie-ins or perimeter fire barriers unassigned

Check the current detail, record the quantity basis and assign a named scope question before bid approval.

REVIEW / 03

Typical-floor assumptions hiding podium differences

Check the current detail, record the quantity basis and assign a named scope question before bid approval.

REVIEW / 04

Cranage, protection and handling omitted from pricing

Check the current detail, record the quantity basis and assign a named scope question before bid approval.

Quantity takeoff or full priced bid?

DeliverableQuantity takeoffFull priced estimate
Measured scopeGlass, framing and scheduled opening quantitiesSame measured scope with agreed cost inputs
PricingNo supplier or installation prices impliedMaterial, fabrication, labour and equipment inputs as commissioned
Required inputsCurrent documents, units and system detailsQTO inputs plus quotations, rate sources, access and commercial assumptions
ReviewSource references, assumptions and RFIsQuantity review plus rate validity and allowance review
AcceptanceWritten scope and deliverable agreementPricing availability and responsibility confirmed before acceptance

Documents to include

  • All facade elevations and system sections
  • Structural embed and slab-edge details
  • Access strategy, specifications and tender scope

Request your curtain wall estimating quote

Drop files here or choose PDF, DWG or ZIP files. Up to 3 files, 50 MB each.

Drawing files are stored with Uploadcare and their links are included in your enquiry. Share only files you are authorised to provide. Privacy information.

Prepare your bid package

Related services in United States